GE broil is burned out picture shows an open element. To test broil set each end of you're wire probes to the element and set you're digital meter to ohms. Picture shows were dial should be set to. A good reading is about 16.5 omhs. A bad reading will show O.L M ohms Indicating an open circuit.The element will need to be replaced .